| Sign In | Join Free | My burrillandco.com |
|
| Ask Lasest Price | |
| Brand Name : | TONHE |
| Model Number : | TH230D05ZZ-3G |
| Certification : | CE、ISO9001 |
| Price : | Factory price |
| Payment Terms : | T/T |
| Supply Ability : | 1000000 pcs per year |
| Delivery Time : | 7 days after payment |
| Input Voltage | 304V-456VAC/380V | Output Current | 5A |
|---|---|---|---|
| Output Voltage | 190V-300VDC/220V | Noise Level | ≤55dB |
| Model Number | TH230D05ZZ-3 | Brand Name | TONHE |
| Output Frequency | 50 Hz | Efficiency | ≥93% |
| Power Factor | ≥0.93 | Communication Protocol | RS485 |
| Power Rating | 1.5KW | Cooling Method | Natural Cooling |
| Ripple Coefficient | ≤1% | Voltage Stabilization Accuracy | ≤±0.5% |
| Dimensions | 325*139*263 mm | Soft Start Time | 3-8 S |
Item | 230D05ZZ-3 | 230D07ZZ-3 | 230D10ZZ-3 | 230D20ZZ-3 | 230D20NZ-3 | 230D30NZ-3 | 230D40NZ-3 | ||
Output Current (A) | 5 | 10 | 10 | 20 | 20 | 30 | 40 | ||
Power (kW) | 1.5 | 2.1 | 3 | 6 | 6 | 9 | 12 | ||
Weight (kg) | 5.2 | 9 | 9 | 16 | 10.5 | 19 | 19 | ||
Cooling Method | Natural cooling | Natural cooling | Natural cooling | Forced air cooling | Forced air cooling | Forced air cooling | Forced air cooling | ||
Internal Heat Sink Temp. Rise | ≤30℃ | ≤30℃ | ≤30℃ | ≤20℃ | ≤20℃ | ≤20℃ | ≤20℃ | ||
Item | Specification | ||||||||
Input Voltage Range (VAC) | Min: 304 / Typ: 380 / Max: 456 | ||||||||
Output Adjustable Range (VDC) | Min: 190 / Typ: 220 / Max: 300 | ||||||||
Voltage Regulation Accuracy | ±0.5% | ||||||||
Current Regulation Accuracy | ±1% | ||||||||
Input Power Factor | ≥0.93 | ||||||||
Charger Efficiency | ≥95% | ||||||||
Maximum Audible Noise (dB) | 50 | ||||||||
Storage Temperature (℃) | Min: -40 / Typ: 25 / Max: 60 | ||||||||
Operating Ambient Temperature (℃) | Min: -10 / Typ: 25 / Max: 40 | ||||||||
Current Unbalance in Parallel | ≤±3% | ||||||||
Startup Delay (Seconds) | 3~8 | ||||||||
Ripple Coefficient | ≤0.2% | ||||||||
Load Level | Class I (Continuous operation at 100% rated output current) | ||||||||
Automatic Current Limiting | When output current exceeds the set current limit value, the charger switches to constant current output and the current will not increase. | ||||||||
Output Overvoltage Protection | Automatically stops output when output voltage exceeds 320±5 VDC to prevent equipment damage. | ||||||||
Output Short Circuit Protection | The module self-protects during an output short circuit to prevent damage; it can automatically resume normal operation once the fault is cleared. | ||||||||
Note | Voltage regulation accuracy does not include the effect of the built-in isolation diode. | ||||||||

|